installation and user instructions
All instructions must be handed to user for safekeeping
Revision A - 06/09
Country(s) of destination - GB/IE
eko 2050
fuel effect gas fire
Vista de página 0
1 2 3 4 5 6 ... 17 18

Resumo do Conteúdo

Página 1 - Revision A - 06/09

installation and user instructionsAll instructions must be handed to user for safekeepingRevision A - 06/09Country(s) of destination - GB/IEeko 2050fu

Página 2 - INSTALLATION INSTRUCTIONS

TESTING FOR SPILLAGE - continuedAll the smoke should be drawn away up the flue. Any smoke returning into the room indicatesthat spillage is occurring.

Página 3 - IMPORTANT NOTES

DISMANTLING THE BURNER TRAYRemove the tray as previously described. The pilot unit can be removed by undoing the tubingnut, the thermocouple nut on th

Página 4 - APPLIANCE DATA

USER INSTRUCTIONSIMPORTANT NOTESThe installation of this fire MUST only be carried out by a competent[1]person in accordance withthe Gas Safety (Insta

Página 5 - SITE REQUIREMENTS

FIREFRONTThis fire is supplied with a particular style of firefront. Use of the firefront will ensure an adequateairflow under the fuelbed for the cor

Página 6 - 203mm (8in) 895mm (35 1/4 in)

FUEL BED LAYOUT (coal effect models) - continued3. Open the bag of 16 moulded coals. All of thecoals are the same. Take five coals and place themas sh

Página 7

FUEL BED LAYOUT (pebble effect option)- continued2. Open the bag of 16 ceramic pebbles. All of thesepebbles are the same size. Take five pebbles andpl

Página 8

FUEL BED LAYOUT (Log effect option) continued2. Open the bag of 9 moulded ceramic logs. All ofthe logs except two are the same. Take the largestlog (n

Página 9 - Fireplace Opening

OPERATING INSTRUCTIONS (manual control models) - continuedWhen the pilot lights after the spark, keep the knob depressed for approximately ten seconds

Página 10 - 2009 Focal Point Fires plc

FLUE SPILLAGE MONITORING SYSTEM - continuedIf pilot disturbance is not the cause, then the ODS safety system may be in operation. Switch theappliance

Página 11 - TROUBLESHOOTING GUIDE

INSTALLATION INSTRUCTIONSPreliminary Notes Before InstallationThis appliance is an Inset Decorative Fuel Effect appliance that provides radiant warmth

Página 12 - USER INSTRUCTIONS

Section1.02.03.04.05.06.06.17.08.09.010.0ContentsImportant NotesAppliance DataInstallation RequirementsSite RequirementsVentilationUnpacking the Appli

Página 13 - Incorrect

INSTALLATION REQUIREMENTSThis appliance MUST NOT be installed into a room containing a bath or shower, or where steammay be present. The fire has bee

Página 14 - © 2009 Focal Point Fires plc

SITE REQUIREMENTSThe fireplace opening should be inspected and repairs made where necessary. Any chair brickmay be left in place.The opening WIDTH and

Página 15

SITE REQUIREMENTS (continued)Any type of fire surround used with this appliance must be adequately sealed to the wall and floor.A combustible shelf ma

Página 16

INSTALLATION INTO A CHAIRBRICKNote: Ensure that the gas supply is isolated before commencing installation of the appliance.Smoke test the flue to ensu

Página 17

OPERATING THE FIRE (manual control models) - continuedTo achieve the HIGH setting, push the control knob in slightly and continue turning anti-clockwi

Página 18

SETTING PRESSURERemove the screw from the pressure test point. The pressure test point is situated on the main injectorpipe next to the pilot.The sett